NHP XL Cytokine Luminex® Performance Premixed Kit
Build your own Luminex Assay with our Luminex Assay Customization Tool.
U.S. orders usually ship in 5-10 business days
Build NowNHP XL Cytokine Luminex® Performance Premixed Kit Summary
Panel | Luminex Performance NHP XL Cytokine Panel |
Assay Type | Magnetic bead-based multiplex assay for the Luminex® platform |
Format | 1 x 96-well microplate and Magnetic antibody-coated beads |
Species | Primate |
Analytes Detected | Please see analyte list in assay customization tool below. |
Performance Validation | Our Luminex High Performance Assays undergo our most extensive validation testing. All Luminex High Performance Assay Panels are validated for use with serum and plasma samples. Some High Performance Assays are additionally validated for cell culture supernatants, milk, saliva, or urine, as indicated on the individual product data sheets. Luminex High Performance Assays are tested for sensitivity (three-quarters the low standard), intra-assay precision, inter-assay precision, and to ensure assay linearity for validated sample types. Recovery values for individual samples in validated sample types are also tested. Validation data for each analyte can be found in the product datasheet. View Luminex High Performance Non-human Primate XL validation data on rndsystems.com. |
Make your selections below to configure your assay
Not finding your analyte of interest? View our complete Luminex offering in the full version of our Luminex Assay Customization Tool. We also offer Custom Luminex Services.
Magnetic Luminex High Performance Assays are flexible bead-based multiplex assays. They allow up to 50 user-defined target analytes to be simultaneously profiled using cell culture supernates, serum, or plasma samples. Some panels are also validated with human milk, saliva, and/or urine samples.
- Simultaneously profile up to analytes of your choice in one sample
- Magnetic format allows for easier wash steps
- Undergoes similar validation testing as Quantikine® ELISA Kits
- Precise and Specific
- Requires a small sample volume (<50 µL)
- Run your assay in just 3-5 hours
- Mass-calibrated standards for consistent results with every new lot of material
- Enough reagents for one 96-well plate
- Premixed cocktail of antibody-coated Magnetic beads
- Premixed cocktail of biotinylated detection antibody
- Standard Cocktail(s)
- Bead Diluent
- Biotin Antibody Diluent
- Calibrator Diluent
- Wash Buffer
- Streptavidin-PE
- One flat-bottom 96-well Microplate
- Foil Plate Sealers (4)
- Mixing Bottle
- Standard Value Card**
- High and low controls with Control Mean Value Card
**A standard curve must be generated each time an assay is run, utilizing values from the Standard Value Card included in the Kit.
Precision
Intra-Assay Precision - is generated from the mean of the %CV's from 40 reportable results across two different concentrations of analytes in a single serum assay Inter-Assay Precision - is generated from the mean of the %CV's across two different concentrations of analytes across 31 different serum assays. |
||
n=40 (20x2 levels) | n=31 | |
---|---|---|
Analyte | Intra-Assay (%CV) | Inter-Assay (%CV) |
BDNF | 8.16 | 13.3 |
CCL2/MCP-1 | 3.02 | 10.5 |
CCL5/RANTES | 3.72 | 17.0 |
CCL11/Eotaxin | 7.98 | 15.4 |
CCL20/MIP-3 alpha | 8.41 | 17.3 |
CD40 Ligand | 9.30 | 15.0 |
CXCL2/GRO beta | 7.76 | 13.1 |
CXCL10/IP-10 | 2.95 | 12.2 |
CXCL11/I-TAC | 6.23 | 13.7 |
CXCL13/BLC | 5.79 | 12.5 |
FGF basic | 5.60 | 13.1 |
G-CSF | 5.55 | 14.2 |
GM-CSF | 7.11 | 14.1 |
Granzyme B | 9.76 | 18.6 |
IFN-alpha | 5.17 | 12.4 |
IFN-beta | 10.9 | 15.2 |
IFN-gamma | 6.36 | 13.0 |
IL-1 beta | 2.55 | 12.7 |
IL-10 | 8.55 | 14.1 |
IL-12 p70 | 4.92 | 17.7 |
IL-13 | 7.97 | 17.5 |
IL-15 | 4.99 | 18.2 |
IL-17A | 4.38 | 19.0 |
IL-2 | 5.32 | 18.1 |
IL-21 | 5.84 | 19.0 |
IL-4 | 4.92 | 17.5 |
IL-5 | 4.14 | 16.5 |
IL-6 | 6.80 | 17.8 |
IL-7 | 6.57 | 17.7 |
IL-8/CXCL8 | 6.87 | 17.5 |
PDGF-AA | 6.52 | 25.0 |
PDGF-BB | 3.37 | 16.9 |
PD-L1 | 8.36 | 19.4 |
TGF-alpha | 5.43 | 18.7 |
TNF-alpha | 3.68 | 17.2 |
VEGF | 4.79 | 18.4 |
Accuracy
Linearity - The data represents mean spiked or natural linearity in serum matrix samples. Samples with natural linearity are marked with an asterisk. Spike Recovery - The data represents mean percent recovery of spiked standards ranging from low, medium, and high concentration in serum matrix samples. |
||
Linearity | Spiked Recovery |
|
---|---|---|
Analyte | Average % | Average % |
BDNF | 114 | HE |
CCL2/MCP-1 | 75 | 135 |
CCL5/RANTES | 98 | HE |
CCL11/Eotaxin | 93 | 138 |
CCL20/MIP-3 alpha | 105 | 111 |
CD40 Ligand | 73 | 105 |
CXCL2/GRO beta | 95 | 81 |
CXCL10/IP-10 | 78 | 72 |
CXCL11/I-TAC | NO | 97 |
CXCL13/BLC | NO | 114 |
FGF basic | NV | |
G-CSF | NO | 67 |
GM-CSF | NO | 111 |
Granzyme B | NO | 122 |
IFN-alpha | NO | 118 |
IFN-beta | NO | 71 |
IFN-gamma | NO | 124 |
IL-1 beta | NO | 68 |
IL-10 | NO | 104 |
IL-12 p70 | NO | 109 |
IL-13 | NO | 118 |
IL-15 | NO | 90 |
IL-17A | NO | 90 |
IL-2 | NO | 89 |
IL-21 | NO | 121 |
IL-4 | NO | 80 |
IL-5 | NO | 95 |
IL-6 | NO | 84 |
IL-7 | NO | 97 |
IL-8/CXCL8 | 121 | HE |
PDGF-AA | 101 | 99 |
PDGF-BB | 103 | HE |
PD-L1 | 80 | HE |
TGF-alpha | NV | |
TNF-alpha | NO | 85 |
VEGF | NO | 97 |
Assays for the Luminex platform are offered as High Performance Assays or Assays. The Luminex High Performance Assays are fully validated panels with a focused selection of analytes. They are available in We Mix, You Mix, and Predetermined formats. The Luminex Assays allows for the maximum number of analytes in a multiplex and is supplied as a premixed kit. View a table comparing the features and benefits of these bead-based multiplex assays.
Magnetic Luminex High Performance Assays are designed for use with the Luminex MAGPIX CCD Imager. Alternatively, kits can be used with the Luminex 100/200™ or FLEXMAP 3D, dual laser, flow-based sorting and detection platforms.
Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. One laser is bead-specific and determines which analyte is being detected. A magnet in the analyzer captures and holds the superparaMagnetic microparticles in a monolayer. Two spectrally distinct Light Emitting Diodes (LEDs) illuminate the beads. One LED identifies the analyte that is being detected and the second LED determines the magnitude of the PE-derived signal, which is in direct proportion to the amount of analyte bound. Each well is imaged with a CCD camera. Kits can also be used with Luminex 100/200 or a Bio-Rad Bio-Plex dual laser, flow-based systems.
Scientific Data
Product Datasheets
Citations for NHP XL Cytokine Luminex® Performance Premixed Kit
R&D Systems personnel manually curate a database that contains references using R&D Systems products. The data collected includes not only links to publications in PubMed, but also provides information about sample types, species, and experimental conditions.
4
Citations: Showing 1 - 4
Filter your results:
Filter by:
-
Chronic alcohol consumption dysregulates innate immune response to SARS-CoV-2 in the lung
Authors: Lewis, SA;Cinco, IR;Doratt, BM;Blanton, MB;Hoagland, C;Newman, N;Davies, M;Grant, KA;Messaoudi, I;
EBioMedicine
Species: Primate - Macaca mulatta (Rhesus Macaque)
Sample Types: Cell Culture Supernates
-
CCX559 is a potent, orally-administered small molecule PD-L1 inhibitor that induces anti-tumor immunity
Authors: Sullivan, KMC;Vilalta, M;Ertl, LS;Wang, Y;Dunlap, C;Ebsworth, K;Zhao, BN;Li, S;Zeng, Y;Miao, Z;Fan, P;Mali, V;Lange, C;McMurtrie, D;Yang, J;Lui, R;Scamp, R;Chhina, V;Kumamoto, A;Yau, S;Dang, T;Easterday, A;Liu, S;Miao, S;Charo, I;Schall, TJ;Zhang, P;
PloS one
Species: Primate - Macaca fascicularis (Crab-eating Monkey or Cynomolgus Macaque)
Sample Types: Plasma
-
Recall responses in the lung environment are impacted by age in a pilot study of Mycobacterium bovis-BCG vaccinated rhesus macaques
Authors: JM Scordo, TJ Piergallin, AM Olmo-Fontá, A Thomas, HP Raué, M Slifka, J Turner
Experimental gerontology, 2022-07-30;167(0):111904.
Species: Rhesus Macaque
Sample Types: Cell Culture Supernates
-
Liver-directed lentiviral gene therapy corrects hemophilia A mice and achieves normal-range factor VIII activity in non-human primates
Authors: M Milani, C Canepari, T Liu, M Biffi, F Russo, T Plati, R Curto, S Patarroyo-, D Drager, I Visigalli, C Brombin, P Albertini, A Follenzi, E Ayuso, C Mueller, A Annoni, L Naldini, A Cantore
Nature Communications, 2022-05-04;13(1):2454.
Species: Macaca leonina
Sample Types: Serum
FAQs
-
Which primate species have been tested with the NHP XL Cytokine Premixed Kit?
The kit has been tested and validated with Cynomolgus monkey and Rhesus macaque samples. The kit is broadly designated as reactive with non-human primate samples due to the expected high homology across primate species.
Reviews for NHP XL Cytokine Luminex® Performance Premixed Kit
Average Rating: 4.7 (Based on 3 Reviews)
Have you used NHP XL Cytokine Luminex® Performance Premixed Kit?
Submit a review and receive an Amazon gift card.
$25/€18/£15/$25CAN/¥75 Yuan/¥2500 Yen for a review with an image
$10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image
Filter by: