Human MICB Alexa Fluor® 350-conjugated Antibody

Catalog # Availability Size / Price Qty
FAB1599U-100UG
R&D Systems Antibodies
1 Image
Product Details
FAQs
Supplemental Products
Reviews

Human MICB Alexa Fluor® 350-conjugated Antibody Summary

Species Reactivity
Human
Specificity
Detects human MICB in direct ELISAs and Western blots. Does not cross-react with recombinant human MICA.
Source
Monoclonal Mouse IgG2b Clone # 236511
Formulation
Supplied 0.2 mg/mL in a saline solution containing BSA and Sodium Azide.
Label
Alexa Fluor 350 (Excitation= 346 nm, Emission= 442 nm)

Applications

Recommended Concentration
Sample
Flow Cytometry
0.25-1 µg/106 cells
K562 human chronic myelogenous leukemia cell line

Please Note: Optimal dilutions should be determined by each laboratory for each application. General Protocols are available in the Technical Information section on our website.

Reconstitution Calculator

Reconstitution Calculator

The reconstitution calculator allows you to quickly calculate the volume of a reagent to reconstitute your vial. Simply enter the mass of reagent and the target concentration and the calculator will determine the rest.

=
÷

Preparation and Storage

Shipping
The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.
Stability & Storage
Store the unopened product at 2 - 8 °C. Do not use past expiration date.

Background: MICB

MICB (MHC class I chain-related gene B) is a transmembrane glycoprotein that functions as a ligand for NKG2D. A closely related protein, MICA, shares 85% amino acid identity with MICB. These 2 proteins are distantly related to the MHC class I proteins. MICA and MICB (MICA/B) possess three extracellular immunoglobulin-like domains, but have no capacity to bind peptide or interact with beta 2-microglobulin. The genes encoding MICA/B are found within the major histocompatibility complex on human chromosome 6. The MICB locus is polymorphic with more than 15 recognized human alleles. MICA/B are minimally expressed on normal cells, but are frequently expressed on epithelial tumors and can be induced by bacterial and viral infections. MICA/B are ligands for NKG2D, an activating receptor expressed on NK cells, NKT cells, gamma δ T cells, and CD8+ alpha beta T cells. Recognition of MICA/B by NKG2D results in the activation of cytolytic activity and/or cytokine production by these effector cells. MICA/B recognition is involved in tumor surveillance, viral infections, and autoimmune diseases. The release of soluble forms of MICA/B from tumors down-regulates NKG2D surface expression on effector cells resulting in the impairment of anti-tumor immune response (1-7).

References
  1. Groh, V. et al. (2001) Nature Immunol. 2:255.
  2. Stephens, H. (2001) Trends Immunol. 22:378.
  3. Bauer, S. et al. (1999) Science 285:727.
  4. Groh, V. et al. (2002) Nature 419:734.
  5. Steinle, A. et al. (2001) Immunogenetics 53:279.
  6. Pende, D. et al. (2002) Cancer Res. 62:6178.
  7. Salih, H. et al. (2003) Blood 102:1389.
Long Name
MHC Class I-related Protein B
Entrez Gene IDs
4277 (Human)
Alternate Names
MHC class I chain-related protein B; MHC class I mic-B antigen; MHC class I polypeptide-related sequence B; MICB; MIC-B; PERB11.2MHC class I-like molecule PERB11.2-IMX; stress inducible class I homolog

Product Datasheets

You must select a language.

x

Product Specific Notices


This product is provided under an agreement between Life Technologies Corporation and R&D Systems, Inc, and the manufacture, use, sale or import of this product is subject to one or more US patents and corresponding non-US equivalents, owned by Life Technologies Corporation and its affiliates. The purchase of this product conveys to the buyer the non-transferable right to use the purchased amount of the product and components of the product only in research conducted by the buyer (whether the buyer is an academic or for-profit entity). The sale of this product is expressly conditioned on the buyer not using the product or its components (1) in manufacturing; (2) to provide a service, information, or data to an unaffiliated third party for payment; (3) for therapeutic, diagnostic or prophylactic purposes; (4) to resell, sell, or otherwise transfer this product or its components to any third party, or for any other commercial purpose. Life Technologies Corporation will not assert a claim against the buyer of the infringement of the above patents based on the manufacture, use or sale of a commercial product developed in research by the buyer in which this product or its components was employed, provided that neither this product nor any of its components was used in the manufacture of such product. For information on purchasing a license to this product for purposes other than research, contact Life Technologies Corporation, Cell Analysis Business Unit, Business Development, 29851 Willow Creek Road, Eugene, OR 97402, Tel: (541) 465-8300. Fax: (541) 335-0354.

FAQs

No product specific FAQs exist for this product, however you may

View all Antibody FAQs
Loading...

Reviews for Human MICB Alexa Fluor® 350-conjugated Antibody

There are currently no reviews for this product. Be the first to review Human MICB Alexa Fluor® 350-conjugated Antibody and earn rewards!

Have you used Human MICB Alexa Fluor® 350-conjugated Antibody?

Submit a review and receive an Amazon gift card.

$25/€18/£15/$25CAN/¥75 Yuan/¥1250 Yen for a review with an image

$10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image

Submit a Review