Human IL-4 QuantiGlo ELISA Kit

Catalog #: Q4000 Datasheet / COA / SDS

Discontinued Product

Q4000 has been discontinued.
View all IL-4 products.
3 Images
Product Details
Procedure
FAQs
Reviews

Human IL-4 QuantiGlo ELISA Kit Summary

Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Assay Length
5.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (150 uL), Serum (150 uL), EDTA Plasma (150 uL), Heparin Plasma (150 uL), Citrate Plasma (150 uL)
Sensitivity
1 pg/mL
Assay Range
1.6 - 5,000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma)
Specificity
Natural and recombinant human IL-4
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.

Product Summary

The QuantiGlo Human IL-4 Chemiluminescent Immunoassay is a 5.5 hour solid phase ELISA designed to measure human IL-4 levels in cell culture supernates, serum, and plasma. It contains E. coli-expressed recombinant human IL-4 and antibodies raised against the recombinant factor. This immunoassay has been shown to accurately quantitate recombinant human IL-4. Results obtained using natural human IL-4 showed dose response curves that were parallel to the standard curves obtained using the recombinant QuantiGlo kit standards. These results indicate that this kit can be used to determine relative mass values for natural human IL-4.

Recovery

The recovery of human IL-4 spiked to three different levels throughout the range of the assay was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Media (n=9) 103 87-115
Citrate Plasma (n=6) 91 83-100
EDTA Plasma (n=6) 92 78-106
Heparin Plasma (n=6) 92 82-102
Serum (n=6) 93 76-109

Linearity

To assess the linearity of the assay, samples containing or spiked with high concentrations of IL-4 in various matrices were diluted with the appropriate Calibrator Diluent to produce samples with values within the dynamic range of the assay.\line

Scientific Data

Product Datasheets

You must select a language.

x

Preparation and Storage

Shipping
The product is shipped at ambient temperature. Upon receipt, store it immediately at the temperature recommended below.
Storage
Store the unopened product at -20 to -70 °C. Use a manual defrost freezer and avoid repeated freeze-thaw cycles. Do not use past expiration date.

Background: IL-4

IL-4 (Interleukin-4) is a cytokine that is primarily expressed by Th2-biased CD4+ T cells, mast cells, basophils, and eosinophils. It promotes cell proliferation, survival, and immunoglobulin class switch to IgG4 and IgE in human B cells, acquisition of the Th2 phenotype by naïve CD4+ T cells, priming and chemotaxis of mast cells, eosinophils, and basophils, and the proliferation and activation of epithelial cells. IL-4 plays a dominant role in the development of allergic inflammation and asthma. The type I receptor for IL-4, which is expressed on hematopoietic cells, is a heterodimer of the ligand binding IL-4 R? and the common ? chain (a shared subunit of the receptors for IL-2, -7, -9, -15, and -21). The type II receptor on nonhematopoietic cells consists of IL-4 R? and IL-13 R?1. The type II receptor also transduces IL-13 mediated signals.

Long Name:
Interleukin 4
Entrez Gene IDs:
3565 (Human); 16189 (Mouse); 287287 (Rat); 397225 (Porcine); 280824 (Bovine); 403785 (Canine); 574281 (Primate); 100302454 (Rabbit)
Alternate Names:
B cell growth factor 1; BCDF; B-cell stimulatory factor 1; BCGF1; BCGF-1; binetrakin; BSF1; BSF-1; IL4; IL-4; IL-4B_cell stimulatory factor 1; IL4E12; interleukin 4; interleukin-4; Lymphocyte stimulatory factor 1; MGC79402; pitrakinra

Assay Procedure

Refer to the product for complete assay procedure.

Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate.
  1.   Prepare all reagents, standard dilutions, and samples as directed in the product insert.
  2.   Remove excess microplate strips from the plate frame, return them to the foil pouch containing the desiccant pack, and reseal.

  3. 100 µL Assay Diluent
  4.   Add 100 µL of Assay Diluent to each well.

  5. 150 µL Standard, Control, or Sample
  6.   Add 150 µL of Standard, control, or sample to each well. Cover with a plate sealer, and incubate at room temperature for 3 hours on a horizontal orbital microplate shaker.
  7.   Aspirate each well and wash, repeating the process 3 times for a total of 4 washes.

  8. 200 µL Conjugate
  9.   Add 200 µL of Conjugate to each well. Cover with a new plate sealer, and incubate at room temperature for 2 hours on the shaker.
  10.   Aspirate and wash 4 times.

  11. 200 µL Substrate Solution
  12.   Add 200 µL Substrate Solution to each well. Incubate at room temperature for 20-40 minutes on the benchtop.
  13.   Determine the RLU of each well using a luminometer.

FAQs

No product specific FAQs exist for this product, however you may

View all ELISA FAQs

Reviews for Human IL-4 QuantiGlo ELISA Kit

There are currently no reviews for this product. Be the first to review Human IL-4 QuantiGlo ELISA Kit and earn rewards!

Have you used Human IL-4 QuantiGlo ELISA Kit?

Submit a review and receive an Amazon gift card.

$25/€18/£15/$25CAN/¥75 Yuan/¥2500 Yen for a review with an image

$10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image

Submit a Review