Human CXCR3 Fluorescein-conjugated Antibody Summary
Met1-Leu368
Accession # P49682
Applications
Please Note: Optimal dilutions should be determined by each laboratory for each application. General Protocols are available in the Technical Information section on our website.
Scientific Data

Detection of CXCR3 in Human Blood Lymphocytes by Flow Cytometry. Human peripheral blood lymphocytes were stained with Mouse Anti-Human CXCR3 Fluorescein-conjugated Monoclonal Antibody (Catalog # FAB160F) and Mouse Anti-Human CD3e Alexa Fluor® 700-conjugated Monoclonal Antibody (FAB100N). Quadrant markers were set based on control antibody staining (IC002F). View our protocol for Staining Membrane-associated Proteins.

Detection of CXCR3 in RPMI8226 Human Cell Line by Flow Cytometry. RPMI8226 human myeloma cell line was stained with Mouse Anti-Human CXCR3 Fluorescein-conjugated Monoclonal Antibody (Catalog # FAB160F, filled histogram) or Mouse IgG1 isotype control antibody (IC002F, open histogram). View our protocol for Staining Membrane-associated Proteins.
Reconstitution Calculator
Preparation and Storage
- 12 months from date of receipt, 2 to 8 °C as supplied.
Background: CXCR3
CXCR3 is a G protein-coupled chemokine receptor that binds the alpha chemokines MIG (CXCL9), IP-10 (CXCL10), and I-TAC (CXCL11). CXCR3 is expressed on activated T cells, B cells, and NK cells.
Product Datasheets
Citations for Human CXCR3 Fluorescein-conjugated Antibody
R&D Systems personnel manually curate a database that contains references using R&D Systems products. The data collected includes not only links to publications in PubMed, but also provides information about sample types, species, and experimental conditions.
24
Citations: Showing 1 - 10
Filter your results:
Filter by:
-
Natural Killer Cells from Allergic Donors Are Defective in Their Response to CCL18 Chemokine
Authors: L Amniai, C Ple, M Barrier, P de Nadai, P Marquillie, H Vorng, C Chenivesse, A Tsicopoulo, C Duez
International Journal of Molecular Sciences, 2021-04-09;22(8):.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Significance of IL-17A-producing CD8+CD103+ skin resident memory T cells in psoriasis lesion and their possible relationship to clinical course
Authors: K Kurihara, T Fujiyama, P Phadungsak, T Ito, Y Tokura
J. Dermatol. Sci., 2019-06-20;95(1):21-27.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Glatiramer Acetate, Dimethyl Fumarate, and Monomethyl Fumarate Upregulate the Expression of CCR10 on the Surface of Natural Killer Cells and Enhance Their Chemotaxis and Cytotoxicity
Authors: Zaidoon Al-Jaderi
Front Immunol, 2016-10-19;7(0):437.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
A distinct plasmablast and na�ve B-cell phenotype in primary immune thrombocytopenia
Haematologica, 2016-03-11;101(6):698-706.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Induction and activation of human Th17 by targeting antigens to dendritic cells via dectin-1.
Authors: Duluc D, Joo H, Ni L, Yin W, Upchurch K, Li D, Xue Y, Klucar P, Zurawski S, Zurawski G, Oh S
J Immunol, 2014-05-16;192(12):5776-88.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Phase I clinical trial of multiple-peptide vaccination for patients with advanced biliary tract cancer.
Authors: Aruga, Atsushi, Takeshita, Nobuhiro, Kotera, Yoshihit, Okuyama, Ryuji, Matsushita, Norimasa, Ohta, Takehiro, Takeda, Kazuyosh, Yamamoto, Masakazu
J Transl Med, 2014-03-07;12(0):61.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Plasmablasts as migratory IgG-producing cells in the pathogenesis of neuromyelitis optica.
Authors: Chihara, Norio, Aranami, Toshimas, Oki, Shinji, Matsuoka, Takako, Nakamura, Masakazu, Kishida, Hitaru, Yokoyama, Kazumasa, Kuroiwa, Yoshiyuk, Hattori, Nobutaka, Okamoto, Tomoko, Murata, Miho, Toda, Tatsushi, Miyake, Sachiko, Yamamura, Takashi
PLoS ONE, 2013-12-10;8(12):e83036.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
CXCL9 causes heterologous desensitization of CXCL12-mediated memory T lymphocyte activation.
Authors: Giegold O, Ogrissek N, Richter C, Schroder M, Herrero San Juan M, Pfeilschifter J, Radeke H
J Immunol, 2013-02-27;190(7):3696-705.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Biomarkers on melanoma patient T cells associated with ipilimumab treatment.
Authors: Wang W, Yu D, Sarnaik A, Yu B, Hall M, Morelli D, Zhang Y, Zhao X, Weber J
J Transl Med, 2012-07-12;10(0):146.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Human TCR gamma delta+ T cells represent a novel target for IL-27 activity.
Authors: Morandi F, Prigione I, Airoldi I
Eur. J. Immunol., 2012-06-01;42(6):1547-52.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Identification of human NK17/NK1 cells.
Authors: Pandya AD, Al-Jaderi Z, Hoglund RA, Holmoy T, Harbo HF, Norgauer J, Maghazachi AA
PLoS ONE, 2011-10-21;6(10):e26780.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
CCR2 identifies a stable population of human effector memory CD4+ T cells equipped for rapid recall response.
Authors: Zhang HH, Song K, Rabin RL, Hill BJ, Perfetto SP, Roederer M, Douek DC, Siegel RM, Farber JM
J. Immunol., 2010-10-27;185(11):6646-63.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
CXCR3-B can mediate growth-inhibitory signals in human renal cancer cells by down-regulating the expression of heme oxygenase-1.
Authors: Datta D, Banerjee P, Gasser M
J. Biol. Chem., 2010-09-20;285(47):36842-8.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Distinct roles for CCR4 and CXCR3 in the recruitment and positioning of regulatory T cells in the inflamed human liver.
Authors: Oo YH, Weston CJ, Lalor PF, Curbishley SM, Withers DR, Reynolds GM, Shetty S, Harki J, Shaw JC, Eksteen B, Hubscher SG, Walker LS, Adams DH
J. Immunol., 2010-02-17;184(6):2886-98.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Phenotypic and functional markers for 1alpha,25-dihydroxyvitamin D(3)-modified regulatory dendritic cells.
Authors: Pedersen AW, Holmstrom K, Jensen SS, Fuchs D, Rasmussen S, Kvistborg P, Claesson MH, Zocca MB
Clin. Exp. Immunol., 2009-07-01;157(1):48-59.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Infiltrated neutrophils acquire novel chemokine receptor expression and chemokine responsiveness in chronic inflammatory lung diseases.
Authors: Hartl D, Krauss-Etschmann S, Koller B, Hordijk PL, Kuijpers TW, Hoffmann F, Hector A, Eber E, Marcos V, Bittmann I, Eickelberg O, Griese M, Roos D
J. Immunol., 2008-12-01;181(11):8053-67.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
The chemokine receptor CXCR3 is degraded following internalization and is replenished at the cell surface by de novo synthesis of receptor.
Authors: Meiser A, Mueller A, Wise EL, McDonagh EM, Petit SJ, Saran N, Clark PC, Williams TJ, Pease JE
J. Immunol., 2008-05-15;180(10):6713-24.
Species: Human
Sample Types: Whole Cells
Applications: ICC -
Expression and role of CCR6/CCL20 chemokine axis in pulmonary sarcoidosis.
Authors: Facco M, Baesso I, Miorin M, Bortoli M, Cabrelle A, Boscaro E, Gurrieri C, Trentin L, Zambello R, Calabrese F, Cassatella MA, Semenzato G, Agostini C
J. Leukoc. Biol., 2007-07-05;82(4):946-55.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Chemokine receptor expression on allergen-specific T cells in asthma and allergic bronchopulmonary aspergillosis.
Authors: Garcia G, Humbert M, Capel F, Rimaniol AC, Escourrou P, Emilie D, Godot V
Allergy, 2007-02-01;62(2):170-7.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Flow-cytometric analysis of cytokine production in human paracoccidioidomycosis.
Authors: Mamoni RL, Blotta MH
Cytokine, 2006-10-11;35(3):207-16.
Species: Human
Sample Types: Whole Blood
Applications: Flow Cytometry -
Plasmacytoid dendritic cell recruitment by immobilized CXCR3 ligands.
Authors: Kohrgruber N, Groger M, Meraner P, Kriehuber E, Petzelbauer P, Brandt S, Stingl G, Rot A, Maurer D
J. Immunol., 2004-12-01;173(11):6592-602.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Aberration of CCR7 CD8 memory T cells from patients with systemic lupus erythematosus: an inducer of T helper type 2 bias of CD4 T cells.
Authors: Sen Y, Chunsong H, Baojun H, Linjie Z, Qun L, San J, Qiuping Z, Junyan L, Zhang X, Jinquan T
Immunology, 2004-06-01;112(2):274-89.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Skewing of cytotoxic activity and chemokine production, but not of chemokine receptor expression, in human type-1/-2 gamma delta T lymphocytes.
Authors: D'Ambrosio D
Eur. J. Immunol., 2002-10-01;32(10):2934-43.
Species: Human
Sample Types: Whole Cells
Applications: Flow Cytometry -
Tumor necrosis factor-dependent segmental control of MIG expression by high endothelial venules in inflamed lymph nodes regulates monocyte recruitment.
Authors: Janatpour MJ, Hudak S, Sathe M, McEvoy LM
J. Exp. Med., 2001-11-05;194(9):1375-84.
Species: Mouse
Sample Types: Whole Cells
Applications: Flow Cytometry
FAQs
No product specific FAQs exist for this product, however you may
View all Antibody FAQsReviews for Human CXCR3 Fluorescein-conjugated Antibody
There are currently no reviews for this product. Be the first to review Human CXCR3 Fluorescein-conjugated Antibody and earn rewards!
Have you used Human CXCR3 Fluorescein-conjugated Antibody?
Submit a review and receive an Amazon gift card.
$25/€18/£15/$25CAN/¥75 Yuan/¥2500 Yen for a review with an image
$10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image